Disconnect electrical charge and negative wire to battery, from the controller card.
Position Set link over both Set Pins.
Replace all power to the controller card.
Ensure that L2 is ON (L1 must be OFF).
SETTING LIMITS
Release the Manual Override, move the gate to the half open position and re-engage Manual
Override.
Press TEST button once. L1 will start flashing, once per second. L2 is OFF.
Press and hold the TEST push button until the STATUS LED illuminates. Release TEST push button.
The gate will start its automatic setup by OPENING. At the OPEN endstop the gate will stop and
reverse slowly. At the CLOSED endstop the gate will stop and reverse. The gate will open quickly
until the magnet reaches the origin sensor. When the gate reaches the origin sensor it will open
slowly. At the OPEN endstop the gate will stop and reverse. The gate will close quickly until the
magnet reaches the origin sensor. At the CLOSED endstop the gate will stop and reverse. The gate
will open to the pedestrian opening point.
Press TEST push button once and release.
Ensure that L2 is ON (L1 should be OFF). This is the end of the automatic setup routine.
AUTO CLOSE
Ensure controller is in programming mode (L2 is ON).
Press and hold the TEST button. L1 will start flashing; once pause, once – twice, when L1 flashes
twice release the TEST push button.
L1 will continue to flash twice. L2 will be OFF.
Press TEST button and wait until the STATUS LED flashes once.
Release TEST button.
L2 will illuminate.
AUTO CLOSE TIME is now ON and set to 15 seconds (Factory default).
Remove the SET link from the set jumper and store the link on one of the pins of the jumper, if
AUTO CLOSE TIME
Ensure that the controller is in programming mode (L2 is ON).
Press and hold TEST button. L1 starts flashing:1 pause, 1-2 pause 1-2-3-, release TEST button.
L1 continues to flash 3 times, press TEST button to set time (One flash of STATUS is equal to
one second of auto-close time).
Release the TEST button after the STATUS LED has flashed the required number of times.
L2 will illuminate.
AUTO CLOSE TIME is now set; remove the SET link from the set jumper and store the link on
one of the pins of the jumper, if you want to exit the program mode.
COLLISION SENSITIVITY
Ensure the controller is in programming mode (L2 is ON).
1 pause, 1-2 = Medium sensitivity (Gate stop with reasonable effort)
1 pause, 1-2 pause, 1-2-3 = High sensitivity (Gate stops with difficulty)
Release the TEST button after required number of flashes.
L2 will go ON.
COLLISION SENSITIVITY is set; remove the SET link from the set jumper and store the link on
one of the pins of the jumper, if you want to exit program mode.
POSITIVE CLOSE
Ensure the controller is in programming mode (L2 is ON).